Sandvik high-performance materials for oil refineries
Sandvik offers a wide range of products for increased refinery productivity. We specialize in corrosion resistant alloys such as duplex stainless steel and nickel alloys. These materials are becoming increasingly important to meet service life demands and increased use of sour crude oil.
If eight shutdowns could be reduced to one, what would that do for your productivity?
http://www.youtube.com/watch?v=_W7rk9AIN4A
By installing heat exchanger tubes in Sandvik SAF 2707 HD hyper-duplex steel in the overhead condensation unit, a German oil refinery managed to reduce the number of shutdowns from eight to one over a 4-year period.
The challenge
A German oil refinery experienced corrosion problems in the overhead condensation unit of its crude oil distillation column. Heat exchanger lifetime was short. Twice every year, the process had to be shut down to replace the carbon steel tube bundle. The oil refinery's goal was to increase the lifetime of the tube material in order to meet a standard 4-year inspection interval for the distillation column. They, therefore, called on Sandvik's metallurgical and materials processing expertise.
The Sandvik solution
As pitting and under deposit corrosion were the reasons for the short heat exchanger life, Sandvik recommended that the refinery should replace the carbon steel tubes with next generation duplex stainless steel grade, Sandvik SAF 2707 HD. This hyper duplex steel has good resistance to chloride induced stress corrosion cracking and its minimal thermal expansion makes it easy to install into a carbon steel construction. Due to the increased corrosion properties the wall thickness of the tubes could be reduced from 2,77 mm to 1,65 mm.
The result
Sandvik SAF 2707 HD tubes were installed in 2006. The new tube bundle was inspected after 6 months and showed slight erosion corrosion. Shutdown after 4 years showed no further erosion corrosion. After cleaning, eddy current testing and hydro testing, the bundle was reinstalled to run for another 4 years.
Reducing the number of shutdowns from 8 to1 over a 4 year period has resulted in fewer steel bundle replacements, which has contributed to increased working safety. Operationally, it has meant large savings in terms of material replacement, manpower and lost production.
Read more about Sandvik SAF 2707 HD
Article functions
Related information
Downloads
-
Case story: Avoiding corrosion in overhead condensers
Select language:
Download Case story: Avoiding corrosion in overhead condensers in English(2.4 MB) Download Case story: Avoiding corrosion in overhead condensers in Deutsch(2.4 MB) Download Case story: Avoiding corrosion in overhead condensers in Español(2.4 MB) Download Case story: Avoiding corrosion in overhead condensers in Italiano(2.4 MB) Download Case story: Avoiding corrosion in overhead condensers in Português(2.3 MB) Download Case story: Avoiding corrosion in overhead condensers in 中文(中华人民共和国)(2.4 MB) Download Case story: Avoiding corrosion in overhead condensers in 日本語(2.4 MB)